Start-Up with Standard DECT Base
1.
switch-on DA1275 near Base Station
2.
switch-on
Repeater Mode
(see Manual of DECT Base Station)
3.
press „Registration" at DECT Base Station
4.
wait till DA1275 is in operational mode
*1)
read pages 8-10 in case PIN of your DECT Base is not „0000"
Hints for PABX and Multicell Systems:
DA1280 has a unique DECT-ID called IPEI. This IPEI you can see on the product label on your
DA1280. It has is a 10-digit Hexadecimal form (HEX). Some DECT Systems (e.g. PABX) request
this PIN in decimal form (DEC)
The conversion HEX (e.g. IPEI 00092268E9) into DEC form is as follows:
convert left-sided 5 HEX digits into decimal (5-digits)
convert residual 5 HEX digits into decimal (7-digits)
IPEI 00092268E9 (HEX) is converted into 001460157929 (DEC)
of DECT Base Station
e.g. 00092
in 00146
HEX
e.g. 268E9
in 0157929
HEX
DEZ
DEZ