American Standard Baby Devoro 2282 Handleiding voor installatie-instructies - Pagina 6
Blader online of download pdf Handleiding voor installatie-instructies voor {categorie_naam} American Standard Baby Devoro 2282. American Standard Baby Devoro 2282 14 pagina's. Baby devoro flushometer bowl
Ook voor American Standard Baby Devoro 2282: Handleiding voor installatie-instructies (13 pagina's)
Roughing-in Dimensions
Right or Left Hand Installation
See (Section 5) for converting Flush
Valve to Left Hand Installation.
73 mm
(2-7/8")
120 mm
(4-3/4")
MANUAL
OVERRIDE
BUTTON
-C-L-
292 mm
(11-1/2")
*-C-L-
152mm MIN.
(6") MIN.
*Note: The Critical Line (-C-L-) on Vacuum
Breaker must typically be 6
fixture. Consult Codes for details.
RECOMMENDED TOOLS; Fig. 2.
1. Teflon Tape
2. Flat Blade Screwdriver
3. Adjustable Wrench
4. Tape Measure
5. Hacksaw
6. Tubing Cutter
7. File
8. For Sweat Connection; Solder and Torch
9. 2.5mm Hex Wrench
10. 1.5mm Hex Wrench
PRIOR TO INSTALLATION
Note: Prior to installing the Selectronic™Flush
Valve the following items must be installed.
1. Toilet
2. Drain line
3. Water supply line
IMPORTANT:
• All plumbing and electrical wiring should be
installed in accordance with applicable codes
and regulations.
• The use of water hammer arrestors is strongly
recommended for commercial applications. All piping
behind the walls should be properly secured and
fastened.
• Water supply lines must be sized to provide an
adequate volume of water for each fixture.
Fig. 1
305 mm MÁX.
(12" MÁX.)
SUPPLY
(1" NPT.)
(NPT de 1")
412 mm
(16-3/16")
108mm-134mm
(4-1/4" TO 5-1/4")
FOR 1-1/2" TOP
SPUD FIXTURES
"
(152mm) above
GENERAL DESCRIPTION:
SELECTRONIC® PROXIMITY TOILET FLUSH VALVE
Exposed Flushometer for 1-1/2" Top Spud Fixtures
Exclusive, self cleaning piston-type flush valve with
proximity operation and manual override. Operates
on DC (battery) power. Recommended operating
pressure 35 to 80 psi. Can install left or right-handed.
Detection Zone can also be adjusted manually, or
FINISHED WALL
with optional remote control.
15˚
DETECTION ZONE
400mm-800mm
(15-3/4 TO 31-1/2)
170 mm MÁX.
(6-11/16") MÁX.
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any components
will void the warranty.
Fig. 2
2
1
5
7
• Flush all water lines prior to operation (See Step 4).
Dirt and debris can cause flush valve to run continuously.
• With the exception of Stop Valve Inlet, DO NOT
use pipe sealant or plumbing grease on any
valve component or coupling!
• Protect the chrome or special finish on the Flushometer.
DO NOT USE toothed tools on finished surfaces to install
or service these valves. Also see "Care and Cleaning"
section of this manual.
• This product contains mechanical and/or electrical
components that are subject to normal wear. These
components should be checked on a regular basis and
replaced as needed to maintain the valve's performance.
3
3
4
10'
6
9
10
M965646 REV. 1.4 (7/15)
8