DAAB OUTPUT CARD DB406 INSTRUCTION MANUAL
Installing the Delta VFD-EL frequency converter
• Modification of the motor winder
The following criteria must be met in order to use the DAAB motor winder with the frequency converter:
• The limit switch cams must be wider than normal.
• FAAC Nordic AB recommends using a motor with a speed of 2,800 rpm.
• Programming the frequency converter
In start mode F XX (XX = frequency) is displayed. Press the ENTER button to enter programming mode (press the button
once for X-). Select the desired group and press ENTER again – (X-XX) is displayed. Select the desired channel and press
ENTER again – (dX) is displayed. Set the desired value, press ENTER again, when the channel is displayed again press
MODE until the display returns to F XX.
• Channel settings in the frequency converter
Channel
no.
00-03
used to display the output frequency during operation
01-00
used to set the maximum output frequency
01-03
used to set the low frequency
01-04
used to set the low frequency voltage
01-05
used to set the start frequency
01-06
used to set the start frequency voltage
01-09
used to set the acceleration time
01-10
Used to define the retardation time
02-00
used to set the control method
02-01
used to set the start method
02-02
used to set the type of stop
02-04
used to block reversing
03-00
used to set the multifunction output
03-08
used to set the internal cooling fan
04-06
used to set the function of input MI4
04-05
used to set the function of input MI3
04-04
used to set the function of input MI1
*
used to set the opening speed
05-00
used to set braking in the opening movement
05-01
used to set the closing speed
05-02
used to set braking in the closing movement
06-01
used to set the over-current protection
06-06
used to set the electronic overload relay
08-08
used to set the current limit for a speed increase
08-15
used to set the number of start attempts before an error message is generated
* = This is set using the arrow keys on the display when the frequency converter is in F XX mode. This setting does not use a
channel.
Description
Fixed
Value to be
value
adjusted
1
70 Hz
7,5 Hz
60 V
1,5 Hz
40 V
1,5 sek
1,5 sek
0
1
1
1
1
2
2
1
0
50Hz
15Hz
30Hz
15Hz
170
2
170
0
5