American-Lincoln ALTO SMART 2000 Elektrische probleemoplossing - Pagina 14

Blader online of download pdf Elektrische probleemoplossing voor {categorie_naam} American-Lincoln ALTO SMART 2000. American-Lincoln ALTO SMART 2000 14 pagina's. Sweeper/scrubber

Conditions necessary for circuit to work
1. Battery voltage at 31.5VDC for 2-3 seconds.
2. Key switch on
3. CB-11 closed
4. Solenoid 8A opens with battery voltage at 31.5(CCV) for 2 to 3 seconds.
5. Water shut off solenoids open
6. Items 4 and 5 can be re -set by turning key off and then back on.
7. TD-2 is closed in forward or reverse.
8. M12 is closed in forward or reverse.
15A
45A
8A
J
C
J
45A
J
45A
RAISE
1
REV.
IGN.
CB-11
LIMIT
3
SW,
11A
ACC.
11B
15A
11
KEY SW.
11A,
FWD.
11B
LIMIT
SW,
M12
29B
87
30
American-Lincoln Technology
SMART 2000 Electrical Troubleshooting Guide

LOW BATTERY SHUT DOWN CIRCUIT

36 V BATTERY BANK
-
CB-6
L
BRUSH
MTR.
+
M
CB-7
MTRS.
MTR.
-
CB-8
N
MTR.
RAISE
42
42A,
42B
41
42
M12
85
86
29,29A
29,29A
LOW VOLTAGE
SHUTDOWN
29C
TD-2
LOW BATTERY SHUT DOWN CIRCUIT
-
+
+
LT.
-
RT.
+
3RD (OPTIONAL)
37
37
37
M10
38
38
37A
8A
37A
TD-2
8
T142
OPTION
77S,77T
WATER
SLOENOIDS
7C,7D
8
LOW VOLTAGE LIGHT
77J
77K
77L
7H
7H
7H
13