TROUBLESHOOTING & MANUAL OVERRIDE
Troubleshooting
In case of power failure, this lift is equipped with a Manual Override Crank that
permits it to be raised or lowered by hand. Before using, check to ensure that the
manual system is required.
Before using the Manual Override Crank, try trouble-shooting by verifying the
following:
Check that the Emergency Stop Switch is pulled out.
Check that the electrical cord is plugged into the electrical outlet.
Check that the building's circuit breaker has not tripped.
Try to run the lift by pushing both the up and down buttons.
Manual Over-Ride Procedure
If, after Troubleshooting as above, the lift still will not run, complete the following
steps:
Step 1
Unplug the lift from the
electrical outlet. Push in the
Emergency Stop Button.
WARNING: Do not service
or operate the Manual
Override Crank while
the lift is connected to
electricity.
For your safety, if you have any questions, please contact your installer, or the
Technical Service Department at 1-866-378-6648.
Step 2
Loosen the screws and
remove the top cap at the
top of the tower.
Hercules II 600 Vertical Platform Lift Owner's Manual | www.Ameriglide.com | 866-378-6648
Step 3
Insert the manual hand
crank onto the upper nut on
the top of the drive screw.
Rotate the crank to raise or
lower the platform.
WARNING: Never operate
the lift while the Manual
Override Crank is inserted
into the lift.