5. ELECTRICAL CONNECTIONS

WARNING!
Before performing electrical connection of the control unit disconnect all electric power and ensure it won't be sup-
plied during the work.
Fig. 5.1. Electrical connections diagram
TRANSFORMER
L1 L2 L3 N PE PE U
L1 L2 L3 N PE
~ 380 – 415 V
4
FU1
FU2
V W
M
HYDRAULIC STATION
MOTOR
~ 380 – 415 V
CONTACTOR
PROTECTOIN
RELAY
1
2
3
ELECTROMAGNETIC
VALVE COILS
1 – leveler lower/raise coil
2 – lip extension coil
3 – lip retraction coil
FU1 fuse 2 A / 500 V AC
FU2 fuse 3,15 A / 250 V AC