DAC Limited RA711 Gebruikershandleiding - Pagina 3
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} DAC Limited RA711. DAC Limited RA711 12 pagina's. Vandal resistant full keypad telephones
Ook voor DAC Limited RA711: Gebruikershandleiding (6 pagina's)
INSTALLATION
The following information is provided for use by the approved
installer or telephone network supplier only. The RA711
telephone can be either wall mounted or top-of-pole mounted.
Wall mounting can be surface, flush or inset into the wall.
Various electrical options are available as defined under the
Electrical Connections section. Make sure that these are set
correctly before finally fitting the unit to the back box.
Wall Flush Installation (as required)
1.
Produce hole in wall 285mm high 120mm wide 60mm
deep.
2.
Use size 8 or 10 screws with rawplugs (4 off) to fix back
box into wall, with cut-out at the bottom
3.
Connect the cabling, Use a 2.5mm socket-head key for
the M4 bolts, through the 4 small holes in the front plate,
to fit the telephone unit to the back-box. Start each screw
by turning several rotations at a time until all 4 screws
are secure. To remove the telephone from the box,
reverse the procedure.
4.
Use any suitable silicone waterproofing sealant (such as
Unibond Waterproof Flexible Frame Sealant) to seal to the
wall. Leave a 12mm to 13mm (0.5") gap at the bottom
for drainage.
Page 2