SECTION 1. SAFETY INSTRUCTIONS
GENERAL
When you receive the pump, check the carton for damage. Open the carton and check the pump for concealed
damage, such as cracks, dents, or a bent base. If you find damage, contact the shipper or the distributor where the
pump was purchased.
The pump must be placed on a solid foundation that will not vibrate and Fluidra USA recommends bolting the
pump to the foundation and providing for adequate drainage should any leaks develope.
BX
½
¾
1
1.5
2
3
ELECTRICAL
All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the
following:
The correct voltage and frequency as specified on the pump data plate is necessary for proper performance and
long motor life. Make sure that the wiring specification meets or exceeds the motor requirements (230v or 115v),
1. When in doubt, use a heavier gauge (larger diameter) wire which helps the motor to run cooler and more
efficiently.
2. Make sure all electrical connections are clean and tight.
3. Cut wires to the appropriate length so they don't overlap or touch when connected to the terminal board, and
insulate all connections carefully to prevent grounding or short circuits.
4. Permanently ground the motor using the green ground terminal located on the inside of the motor canopy,
under access plate.
5. Use the correct wire size and type specified by National Electrical Code, "NEC" (or Canadian Electric Code, "CEC",
for Canada). Make sure the ground wire is connected to an electrical service ground.
6. Electrically bond the motor to the pool structure in accordance with the National Electrical Code (or Canadian
Electric Code for Canada). Use a solid No. 8 AWG or larger copper conductor.
7. Additonally, run a wire from the external bonding point to the pool bonding structure following the NEC/CEC.
8. Connect the pump to a permanent/dedicated circuit. Make sure no other lights or appliances are on the same
circuit.
WARNING
Make sure all electrical breakers and switches are turned off before wiring motor.
SUPPLY WIRE SIZES (AWG)
Size and length based on horse power
CTX
115 volts
50 ft.
100 ft.
¾
14
12
1
12
12
1.5
12
10
2
10
10
2.5
10
8
-
-
-
see the Table 1 (above) for recommendations.
230 volts
150 ft.
50 ft.
100 ft.
10
14
14
10
14
14
8
14
14
8
14
14
8
14
-
12
Table 1
2
150 ft.
14
14
14
12
12
12
12
10