Astria Fireplaces Polaris36ZEP Handleiding voor verzorging en gebruik - Pagina 6

Blader online of download pdf Handleiding voor verzorging en gebruik voor {categorie_naam} Astria Fireplaces Polaris36ZEP. Astria Fireplaces Polaris36ZEP 18 pagina's. Outdoor decorative gas fireplace

Astria Fireplaces Polaris36ZEP Handleiding voor verzorging en gebruik

Maintenance Schedule

Annually (Before the onset of the Burning Season)
MAINTENANCE TASK
Inspecting/Cleaning Burner, Logs
and Controls
Inspecting/Cleaning Pilot and Burner
Appliance Checkout
Replacing Volcanic Stone
Replace Spent Batteries
Periodically (After the Burning Season)
MAINTENANCE TASK
Cleaning Firebox Interior
Replace Spent Batteries

Reset Limit Switch

Step 1. Remove bottom middle refractory
panel (#4) and valve cover assembly (#9) to
gain access to the limit switch (#25).
Step 2. Slide your left hand into the fireplace
and use your middle finger to feel for two
wires connected to the limit switch. Follow
up, in between the two wires is the reset but-
ton, located on the back of the limit switch.
Refer to Figure 4 and Figure 5 on Page 7 for
more detail.
6
ACCOMPLISHING PERSON
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Homeowner/Qualified Services
Technician
Homeowner
ACCOMPLISHING PERSON
Homeowner
Homeowner
NOTE: Make sure you have new batteries
and all volcanic stone has filled the pan and
that the logs are set correctly.

Burner Adjustments

The following paragraphs address burner
adjustment concerns and procedures.
PROCEDURE
Inspect valve and ensure it is properly operating. Check piping for leaks.
Vacuum the control compartment, fireplace logs and burner area.
Refer to Figure 10 (Dexen) on Page 9. Remove any surface build-up
on pilot and burner assembly. Wipe the pilot nozzles, igniter/flame rod
and hood. Ensure the pilot flame engulfs the flame sensor as shown.
Perform the appropriate appliance checkout procedure detailed in this
manual.
Remove old volcanic stone and vacuum the stone placement area. Place
new volcanic stone as described in this document.
Locate and remove the four (4) screws retaining the stainless J-Box
cover. Remove the battery pack and replace the two (2) "D" cell batteries.
PROCEDURE
Carefully remove logs and decorative volcanic stone. Vacuum out interior
of the firebox. Clean firebox walls and log grate. Replace logs, Rockwool
and volcanic stone as detailed in this manual.
Locate and remove the four (4) screws retaining the stainless J-Box
cover. Remove the battery pack and replace the two (2) "D" cell batteries.

Flame Appearance and Sooting

Proper flame appearance is a matter of taste.
Generally most people prefer the warm glow of
a yellow to orange flame. Appliances operated
with air shutter openings that are too large will
exhibit flames that are blue and transparent.
These weak, blue and transparent flames are
termed anemic. If the air shutter opening is too
small excessive sooting may develop.