WIRING DIAGRAMS

Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics attached directly to the appliance on
a pullout panel located within the control compartment.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGER-
OUS APPLIANCE OPERATION.
NOTES:
1. If any of the original wire as supplied must be replaced, use Type AWM 105°C - 18 gage wire ONLY.
2. Electrical Rating: 3V DC.
CAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper operation after servicing.
WALL SWITCH BOX
COVER
REMOTE WALL SWITCH
WALL SWITCH BOX
REMOTE
WALL
SWITCH
Figure 11

WARRANTY

Your gas appliance is covered by a limited twenty
year warranty. You will find a copy of the war-
ranty accompanying this manual. Please read
the warranty to be familiar with its coverage.
Retain this manual. File it with your other docu-
ments for future reference.

PRODUCT REFERENCE INFORMATION

We recommend that you record the following important information about your fireplace.
Please contact your Astria™ dealer for any questions or concerns.
Your Fireplace's Model Number ________________________________________
Your Fireplace's Serial Number ________________________________________
The Date On Which Your Fireplace Was Installed ___________________________
The Type of Gas Your Fireplace Uses ____________________________________
Your Dealer's Name ________________________________________________
10
ELECTRONIC IGNITION WIRING DIAGRAM
WEATHER
SEAL
D-CELL BATTERIES
BLACK
BATTERY
BROWN
BROWN

REPLACEMENT PARTS

A complete parts list is found at the end of
this manual. Use only parts supplied from the
manufacturer.
Normally, all parts should be ordered through
your Astria distributor or dealer. Parts will be
shipped at prevailing prices at time of order.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
IGNITER MODULE - 3V
ORANGE
BLACK
RED
HIGH LIMIT
SWITCH
GREEN
UMBILICAL CORD (9 Feet)
PILOT BURNER
IGNITER-SENSOR
ASSEMBLY
IGNITER
ROD
BLACK
SPARK WIRE CABLE
BLACK
PILOT SENSOR CABLE
PILOT TUBE
ELECTRONIC GAS CONTROL VALVE - DEXEN
(THTP)
(TP)
HI
LO
(TH)
BLACK JUMPER
Schematic Representation Only
When ordering repair parts, always give the
following information:
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.
If you encounter any problems or have any
questions concerning the installation or applica-
tion of this system, please contact IHP directly:
INNOVATIVE HEARTH PRODUCTS
1508 Elm Hill Pike, Suite 108
Nashville, TN 37210
www.Astria.us.com
FLAME
SENSOR