position the tray over the desired
location for the shower and outlet
pipe. mark around the edge
of the shower tray.
220 mm
220 mm
355 mm
355 mm
the waste area must be supported
with additional noggins, 220 mm
around the waste. additional
noggins or joists must be used on
all tray edges and between joists
centres at a minimum of 355 mm.
apply grab adhesive to all the
contact points between the tray,
joists and noggins. lower the tray
over the waste position and firmly
secure the tray into position and
check all 4 sides are level again.
Order: 01905 823 299
|
orders.akw-ltd.co.uk
Wooden Floor Installation
For 'in' floor installation, cut into
the flooring, taking care not to cut
through supporting joists or any
plumbing or electrical wiring.
220 mm
355 mm
Install the waste drain trap and
waste outlet pipe. Do not cut into
the joists, always drill through
when connecting to
the waste outlet pipe.
attach the waste trap to the tray
with the waste clamping ring, see
separate waste instructions.
apply a waterproof membrane to
the whole of the showering area,
see manufacturers instructions.
Carefully remove the floor boards
and locate the waste outlet pipe.
For 'on' floor installation, remove
the floor boards around
Water test the waste drain trap for
flow and any leaks. Ensure that the
rubber seal is in place.
remove any debris and ensure
that there are no sharp edges or
raised areas and check levels.
Safety flooring or tiles should finish
flush up to the edges of the tray
and sealed with sealant. protect
the waste trap from debris
Technical Support: 01905 560 219
the waste area.
during installation.