ASTRO-PHYSICS German Equatorial 1200GTO Upgrade Vervanging

Blader online of download pdf Upgrade Vervanging voor {categorie_naam} ASTRO-PHYSICS German Equatorial 1200GTO. ASTRO-PHYSICS German Equatorial 1200GTO 5 pagina's. Polar forks s1200pf-b

Upgrade replacement of
1200GTO Polar Forks S1200PF-B
Although the installation of the new forks would seem to
be fairly obvious the weight of the RA Axis, location of
washers, awkwardness of position and gravity all add
complexity. We advise that you follow these instructions,
rather than "Wing it". This will assure that all of the
pieces are assembled back properly and will prevent
damage to the paint finish.
1-A
1-A
2-A
2-A
2-B
2-B
3-A
3-A
3-B
3-B
3-C
3-C
3-D
3-D
3-E
3-E
3-E
3-E
4-B
4-B
4-A
4-A
Step 1 - Remove the declination axis assembly,
GTO control box unit and any cables from the
mount. If your mount has the GTOCP1 control box,
you may elect to leave it attachted since it is more
difficult to remove than the GTOCP2 control box.
You may leave the right ascension assembly on
your pedestal, pier or tripod for most of the
upgrade. Have a table close by to set parts on.
Please note that the polar axis you will be removing
weighs approximately 36 pounds. Although not
mandatory, it would be best to have an assistant for
this upgrade.
Step 2 – Look at the interface between the polar
fork and right ascension housing. There are 4 flat
washers that will be dropping out as disassembly
takes place. Be aware of their location. All four are
the same size and thickness.
Step 3 – Using a ¼ inch hex key, remove the lock
knobs from both sides of the polar forks. The
washers resting between the forks and the housing
may fall out at this time. Be prepared to catch
them. If they do not drop out, release the torque on
the rear screws approximately one turn to release
them. (3-A) DO NOT remove the rear screws at
this time.
There is a possibility that the knob under the
worm drive bracket will hit the end of the cut out in
the bracket. (3-C) In this case the length of the
screw in the knob is slightly too long. Place a piece
of tape on the bracket to prevent scaring of the
parts.(3-D) Rotate the knob out until it hits the tape
and with a 1/4 inch hex key in the center screw, try
to "wiggle it free. If this does not work try the
following. Remove the set screw in the knob using
a 5/64 hex key. (3-E) Push into the set screw hole,
as deeply as possible a 1/8 inch hex key. Make a
cushion of cloth or paper and locate it under the
hex key and fork stiffener. Using a 1/4 inch hex
key attempt to break free the 5/16 socket head cap
Please gather the following tools
and materials to aid in the
replacement process.
¼ inch hex key
1 inch wide masking or electrical tape
Wood 2x4, maximum length 9 inches
Approximately 10) 3 ½ x 5 inch
pieces of single corrugation
cardboard
3/32 inch hex key
3/16 inch hex key
Table near telescope pier.
06/22/2004