Cojali jaltest TOOLS WST Gebruikershandleiding - Pagina 9
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Cojali jaltest TOOLS WST. Cojali jaltest TOOLS WST 14 pagina's. Wear sensor tester
2.2.1 END-OF-PAD/ 2-WIRE SENSORS
1.
Turn sensor type selector to the position of the end-of-pad/2-wire sensor
2.
OK
If the
LED lights up in green, the wear is correct
3.
NOT OK
If the
LED lights up in red, it must be visually inspected, since Jaltest WST
does not indicate any wear value
Note: If Jaltest WST indicates a value below 0.2V or above 4.8V, the brake caliper
sensor is an end-of-pad/2-wire sensor and, therefore, it cannot be checked with
accuracy the wear state of the pad. The inspection must be performed visually.
2.2.2. CONTINUOUS SENSORS
1.
Turn sensor type selector to the position of the corresponding continuous sensor.
See
table 2
2.
Compare the value shown with those of
MB, SCANIA, (+) and with
3.
If the value shown in Jaltest WST is below 2.7V, the
If the value shown in Jaltest WST is above 2.7V, the
this case, the wear of brake pads and discs must be visually inspected and it should
be considered to replace them.
Note: If it is a continuous sensor and Jaltest WST indicates a value below 0.2V or
above 4.8V, the component might have an open circuit or a short circuit.
table 3
table 4
or sensors in MAN and MERITOR
English
in case of sensors in DAF, IVECO,
OK
LED lights up in green
NOT OK
LED lights up in red. In
9