Setting humidity calibration

:calh,50*
:calh
50
*

Resetting calibration values

:calreset*
:calreset
*

Getting calibration values

:calget*
:calget
*

Send GPS-Data to Mount (Standard Firmware only)

:mg,1*
:mg
1
*

Send Meteo-Data to Mount (Standard Firmware only)

:mm,1*
:mm
1
*
Update Mount refraction data (10Micron specific Firmware only)
:ur,1*
:ur
1
*
Update Mount time initially (10Micron specific Firmware only)
:ut,1*
:ut
1
*
Set calibration value for pressure
Calibration value multiplied by 10, e.g. 5.0°C
End of message indicator
Resets all calibration values
End of message indicator
Resets all calibration values
End of message indicator
Set's if GPS-Data should be sent to the
Mount
Enable sending (0 = disabled)
End of message indicator
Set's if Meteo-Data should be sent to the
Mount
Enable sending (0 = disabled)
End of message indicator
Set's if the mount's refraction data should be
updated periodically
Enable sending (0 = disabled)
End of message indicator
Set's if the mount's time should be updated
initially
Enable sending (0 = disabled)
End of message indicator