COLDBUSTER FLOORHEATING CB Smart2 Gebruiksaanwijzing - Pagina 9
Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} COLDBUSTER FLOORHEATING CB Smart2. COLDBUSTER FLOORHEATING CB Smart2 10 pagina's.
The resistance value of the floor sensor at the corresponding
Temperature
temperature point (Ω)
0-3950
1-3380
2-3700
0 °C
32800
26050
30286
10 °C
19733
17630
19055
25 °C
10000
10000
10000
30 °C
7905
8331
8165
16. Factory Reset:
All parameters are restored to default values.
TROUBLESHOOTING
Room Sensor Error!:
Room sensor short-circuit or disconnec�on.
Floor Sensor Error!:
Floor sensor short-circuit or disconnec�on.
DIMENSIONS(mm)
15
136
3-3600
4-3740
34423
34720
22217
22328
12000
12000
9869
9854
26
60
52
13
INSTALLATION AND WIRING INSTRUCTIONS
Separate the panel from the back
sec�on: insert the screwdriver into
two holes under the thermostat and
gently pry it. Refer to picture above.
Step 1
Connect the wire as shown in
the wiring instruc�on.
Step 2
14