Basic Serial Functional Specification for LV-5210/7215/7210
7.3.9
"24" [CR]
Status: Processing Power Save・Cooling Down
Cooling down by the power management function in the e setting menu.
The control command is invalid.
This Power Save・Cooling Down moves to Power Save after the cooling down time.
Status:
No signal
POWER SAVE
Response:
7.3.10 "04" [CR]
Status of Power Save
The status is Power Save by the Power management function in setting menu.
7.4 Input Mode Read COMMAND
COMMAND
"CR1" [CR]
Detail
Get selected Input No.
Acceptable
Response
Unacceptable

7.5 Lamp Time Read COMMAND

COMMAND
"CR3" [CR]
Detail
Get total lamp running hours.
Acceptable
Response
Unacceptable
POWER
"00"
After 5 minutes with no signal
"%1" [CR]
"1" = Computer1 is selected
"2" = Computer2 is selected
%1
"3" = Video is selected.
"?" [CR]
"%1" [CR]
Show as 4 digits
%1
Ex.: "0410"[CR] ・・・・410 hours
"?" [CR]
SAVE
"24"
COOLING
DOWN
"04"
after about 90 seconds