Introduction

Cansec's Via Universal Wireless Lock brings the benefits of wireless to virtually any access control
system. Unlike other wireless locks, it can be configured in under 5 minutes and does not require
a PDA, tablet or smart phone to initialize it. A few simple DIP switch settings and you are done.
The Via Lock operates with 125 kHz HID and AWID cards and supports all Wiegand formats up
to 64 bits. Locks communicate wirelessly to a Via Hub which can be located up to 70/170 ft (21/52
m) away in a typical office environment. Each Hub can support two Via Locks.
Three status LEDs on the reader make troubleshooting simple. The lock is powered by 4 AA batter-
ies which will last 1 to 2 years in a typical application (depending on setup).
Wiegand data is sent wirelessly to the Via Hub, which in turn sends the data to a Wiegand reader
port on the associated access control panel for verification. If the lock relay operates, indicating that
access is granted, the Hub will send a wireless unlock command to the reader at which the card was
presented.
The high quality ANSI Grade 1 cylindrical lockset is suitable for use on interior or exterior wood
or hollow metal doors from 1

KEY FEATURES

• Configure in less than 5 minutes
• Supports 125 kHz HID and AWID cards
• Supports ANY Wiegand format to 64 bits
• Works with ANY access control panel
• Powered by 4 AA batteries
• Up to 70/170 ft (21/52 m) range
(selectable via DIP switch)
NOTE
Via Universal Wireless Lock does not support UNLOCK SCHEDULES.
IMPORTANT
The unlock time for the access control panels used with the Via Locks must be a maximum of
three (3) seconds.
" to 2" in thickness (35-51 mm).
3
8
Via Wireless Lock
Installation Manual
• Forced entry detection
• Low battery output
• Use on interior & exterior doors
• Built-in self diagnostics
• Wake up every 4
• Via Universal Hub supports 2 locks
• Supports door contact input
• Integrated REX switch
minutes or 30 seconds