Care and Maintenance Instructions Model : Z3450
MAINTENANCE FOR SINGLE HOLE/ADORE SINGLE LEVER TAP WARE WITH ONE LEVER DESIGN
INSTRUCTIONS FOR REPLACEMENT OF THE C3009 CARTRIDGE
See also:- https://youtu.be/mpdiKSEoznY
Do not replace the cartridge if there is low flow or no flow. Low flow or no flow is caused by obstruction or kinking of
supply hoses.
 Turn off the hot and cold supply lines to the tap.
(Not shown).
 Remove handle as per Removing/ Replacing
handle directions.
 Remove the cartridge nut with a 27mm socket
set or shifter.
 Install new cartridge.
 Ensure that the cartridge is correctly located
by inserting the alignment tabs A and B, into
the alignment slots.
Further information Phone (03) 9761 4603
8
Once the cartridge nut is loose; simply
the cartridge by pulling it from cartridge seating
position.
 To reinstall simply revers the above procedure.
 Install the handle, retaining flange and retaining screw.
DO NOT USE A SHIFTER TIGHTEN BY HAND ONLY!
 Turn on supply line and test for leaks. (Not shown).
Note: Do not over tighten as this could damage the
ceramic cartridge!