Asus UPX-EDGE-ASL01 Gebruikershandleiding - Pagina 26
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Asus UPX-EDGE-ASL01. Asus UPX-EDGE-ASL01 35 pagina's. Maker board system
LED Assignment:
LED Name
CAN 1
CAN 2
2.3.10
CAN Term (DIP Switch) (14)
The controller provides one built-in 120Ω terminal resistor for CAN 1/CAN 2 ports,
users can decide if it is enabled or not.
The following DIP switch status presents the condition if the terminal resistor is active
(default) or inactive.
Pin No
1
2
Chapter 2 – Hardware Information
LED Color
Description
Green
LED flashing while CAN transmission
Red
LED flashing while error occurred
Green
LED flashing while CAN transmission
Red
LED flashing while error occurred
Description
ON: Active CAN1 terminal resistor (default)
OFF: Inactive CAN1 terminal resistor
ON: Active CAN2 terminal resistor (default)
OFF: Inactive CAN2 terminal resistor
15