Akytec PD111 Gebruikershandleiding - Pagina 11

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Akytec PD111. Akytec PD111 13 pagina's. Pressure transmitter for general industrial application

Faults

8. Faults
Table 8.1 Faults
No output signal
Output signal is unsta-
ble or remains con-
stant even if pressure
is changing
* Nota: When cleaning the process connection any mechanical influence on the dia-
phragm must be avoided.
akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de
Fault
Possible cause
Cable breakdown
Electrical short in power
supply circuit
Voltage reversal
Process connection is
blocked up
Loss of pressure integrity in
the process connection
Missing electrical contact
Remedy
Check the cable line
Check the cable line
Reverse polarity
Clean the connection*
Find the leakage and fix it
Switch off power supply and
check the contacts
10