4. Parameter
: Parameter Setting
Run mode
Push for 3se.
SEL
the SEL button
Setting
the Temperature
Parameter
SEL
SEL
END
: Temperature Setting
No
Menu
4 0001
Temperature setting
운전모드
: Setting Group 1 Parameter
3초간 입력
SEL
No
Menu
희망온도
변경방법
4 0002
Select Temperature Unit
Present value decimal
4 0003
point display method
Parameter
4 0004
Select Control Type
SEL
SEL
4 0005
Control Deviation
4 0006
ON Delay time
END
4 0007
ON Delay time Unit
4 0008
Defrost cycle setting
4 0009
Defrost time setting
Defrost termination
4 0010
temperature
4 0011
Max. Set Point
4 0012
Min. Set Point
4 0013
Buzzer Delay Time
4 0014
Sensor Correction
4 0015
Sensor Type
4 0016
Communication ID
4 0017
Communication Baud rate
: TRIP / ALARM MESSAGE
No
Menu
1
Sensor Open
2
Sensor Short
3
Sensor input lower limit
4
Sensor input upper limit
● Press the SEL button foe 3 sec while operating to change the set temperature.
● Press the PRG button for 3 sec to enter the group 1 parameter.
Push for 3se.
PRG
the PRG button
● The SEL button is a function for moving the next menu and saving the setting value
Setting
at Parameter Setting.
the Group 1
● The set value flashes every 0.5 sec, And the set value is set (changed) by using
the ▲ key or the ▼ key.
Parameter
● When the set value is changed and the SEL button is pressed for 3 seconds,
the current temperature is displayed.
● If there is no key input for 60 seconds during setting, it automatically returns to
Parameter
END
operation mode.
Push for 3se.
SEL
the SEL button
Code
Unit
Step
℃ / ℉
1
ST
3초간 입력
PRG
Code
Unit
Step
설정1그룹
변경방법
℃ : Celsius
UNT
1 : No decimal point
DP
Parameter
O F F : Display
T Y P
℃ / ℉
0.1
D I F
Parameter
sec
1
D L T
END
-
1
DLU
SEL
3초간 입력
hour
1
DEF
min
1
DET
℃ / ℉
1
DEP
℃
1
U H
℃
1
U L
초
1
B UR
K
1
C O R
T01 : TH01,
SEN
-
1
ID
BPS
24:2400
Code
O P N
5 H T
Occurs if the sensor input is below the sensor range.
L L L
Occurs if the sensor input is above the sensor range.
H H H
Min.
Max.
U L
U H
Min.
Max.
℉ : Fahrenheit
0.1 : Decimal point
C : Cooling
H : Heating
1
99
0
999
0
1
0
24
0
60
U L
UH
U L
105
-55
U H
OFF
999
-199
199
T02 : TH02
1
128
48:4800
96:9600
Setting
Need to check the sensor
Need to check the sensor
- 3 -
Default
Note
-20
Default
Note
℃
0.1
C
2
60
0
0 : Sec., 1 : Min.
5
5
5
100
-50
OFF
-2
THO1 : NTC5K,
T01
TH02 : NTC10K Temp. Sensor
1
96
Movement
Release
Stop
Automatic return
Stop
Automatic return
Stop
Automatic return
Stop
Automatic return