Seal up the unused cable gland using a sealing bolt (included in the delivery).
1
2
3
Terminal assignment
M12 connector
M12, 4 pins: Pin 1
M12, 4 pins: Pin 3
M12, 5 pins: Pin 2
M12, 5 pins: Pin 4
M12 connector
for serial data lines
male
female
Clamps with the same designation are internally connected to each other and identical in function.
Maximum load on the internal clamped connections UB-UB and GND-GND is 1 A each.
Signals A and B are decoupled with an inductivity of 100 nH each.
Assembly of basic encoder and bus cover:
Carefully plug the bus cover onto the D-SUB connector of the basic encoder, then press it over the seal
taking care not to tilt it.
Tighten both fastening screws firmly in the same direction.
The bus cover must fully rest on the housing of the basic encoder and be firmly screwed on.
The encoder housing and braided shield of the connecting cable are only ideally connected if the bus cover is
resting fully on the basic encoder (positive locking).
Manual_ProfibusDPV2_BIDE_EN.docx
22.11.12
Cable gland
Clamp:
Significance
UB
Supply voltage 10...30 VDC
GND
Ground connection related to UB
A
Negative serial data line
B
Positive serial data line
for voltage supply
10/41
M12 connector
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany