MOUNTING / DRIVE SIDE MOUNTING OF THE TORqUE ARM
)
4.4
Drive side mounting of the torque arm
Lifetime restrictions and angle error of the encoder
A play of just ±0�03 mm, results in concentricity error of the encoder of 0�06 mm�
That may lead to a large angle error, see
» Mount the torque arm without play�
11/33
section 4.5, page
MB252EN - 11173969, 16A1, Baumer_HMG10-DeviceNet_II_EN
12�