Baumer Hübner
9
8
7
6
Ill. 9: Connecting the supply cable
1
Torx/slotted head screw M4x32mm
3
Washer A4 (DIN 137)
5
Cable shield
7
Cable gland M16x1.5 mm (matching ca-
ble diameters 5-9 mm)
9
D-SUB port (for D-SUB connector)
Tools
n
T20
n
Instruction:
a) Loosen the screws at the terminal box.
b) Remove the DeviceNet terminal box from the encoder.
c) Loosen the cable gland at the terminal box.
d) Insert the connection cables into the cable glands.
e) Assign the supply cables to the terminals.
f) Attach the cable gland to the terminal box.
g) Mount the terminal box at the encoder. For doing so, tighten the screws with a torque of 2-3
Nm.
V1 | PMG10 & PMG10P DeviceNet
1
2
3
4
17 mm
5
2
Bus terminal box Profibus DP
4
D-SUB connector
6
Connection cable (diameter 5-9 mm)
8
Terminals
Operating Manual
Electrical installation
|
6
23