Instruction:
a) Loosen the screws at the terminal box.
b) Lift the terminal box off the encoder.
c) Loosen the cable gland at the terminal box.
d) Insert the supply cables into the cable gland, let stick out approx. 50 mm of cable.
e) Assign the supply cables to the terminals.
f) Attach the cable gland to the terminal box.
g) Mount the terminal box at the encoder. For doing so, tighten the screws with a torque of 2-3
Nm.
6.2.8

Terminals assignment

NOTICE
Operating voltage present at the outputs results in encoder damage.
The encoder might be damaged by any operating voltage being present at the outputs.
a) Make sure that no operating voltage is present at the outputs.
1
2
3
4
5
6
7
Ill. 13: Terminals assignment
1
3
5
7
9
11
13
I
Speed switch (optional)
II
Additional output incremental (optional)
III
Programming interface (programmable product variant only)
6.3

Z-PA.SDL.1 WLAN adapter: Programming device for HMG10P/PMG10P

INFO
For detailed function descriptions refer to the WLAN adapter installation and operating instruc-
tions.
V1 | PMG10 & PMG10P EtherCAT
I
dnu / SP+ 
II
dnu / A− 
II
dnu / B− 
II
0 V 
II
nE+ 
II
dnu / R+ 
III
dnu / SA 
8
9
10
11
12
13
14
2
dnu / A+ 
4
dnu / B+ 
II
6
Ub 
8
dnu / SP− 
II
10
nE− 
12
dnu / R− 
14
dnu / SB 
Operating Manual
Electrical installation
II
II
I
II
III
|
6