MOUNTING / MOUNTING THE SPRING DISK COULING TO THE ENCODER
4.

MOUNTING

4.1

Mounting the spring disk couling to the encoder

We recommend using the Baumer Hübner spring disk coupling K 35, see
9, available as accessory. When other couplings are used pay attention to manufactu-
rer's notes.
)
4.2

Mounting to drive shaft

Lifetime restrictions and angle error by radial deviations
High runout of the drive shaft can cause encoder angle error.
High runout of the drive shaft can cause vibrations, which can shorten the lifetime of
the encoder.
» Lubricate drive shaft!
» Minimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
The encoder must be mounted with cable connection facing downward and not
i
exposed to water.
7/25
2�5 mm
8
M
= 100 Ncm
t
7
10 mm
6
MB247EN - 11171697, 16A2, Baumer_PMG10-ProibusDP_II_EN
section 4.4, page