ELECTRICAL CONNECTION / PROFIBUS DP
5.

ELECTRICAL CONNECTION

Proibus DP
5.1
Please ind a detailed instruction for the Proibus DP interface and the device de-
i
scription ile in the manual on the CD provided with the device.
5.1.1

Features

Bus protocol
Proibus-Features
Data Exch. functions
Preset value
Parameter functions
Diagnostic
Default settings
* Je nach Version
11/25
Proibus DP V0* or Proibus DP V2*
Proibus DP V0 = Device Class 1 and 2
Proibus DP V2 = Device Class 3 and 4
Input: Position value
Output: Preset value
The „Preset" parameter can be used to set the encoder
to a predeined value that corresponds to a speciic axis
position of the system.
Rotating direction:
The relationship between the rotating direction and
rising or falling output code values can be set in the
operating parameter.
Scaling:
The parameter values set the number of steps per turn
and the overall resolution.
The encoder supports the following error messages:
- Position error
User address 00