Baumer Hubner Berlin PMG10 Montage- en bedieningsinstructies - Pagina 19

Blader online of download pdf Montage- en bedieningsinstructies voor {categorie_naam} Baumer Hubner Berlin PMG10. Baumer Hubner Berlin PMG10 32 pagina's. Absolute encoder
Ook voor Baumer Hubner Berlin PMG10: Montage- en bedieningsinstructies (32 pagina's), Bedieningshandleiding (44 pagina's)

Baumer Hubner Berlin PMG10 Montage- en bedieningsinstructies
5.1.4
View in bus connecting box DeviceNet [A]
Terminal assignment
DRAIN Shield
GND
UB
CAN_H CAN bus signal (dominant HIGH)
CAN_L CAN bus signal (dominant LOW)
i
Terminals of the same significance are internally connected and identical in their
functions� Max� load on the internal terminal connections UB-UB and GND-GND
is 1 A each�
5.1.5
Setting for the terminating resistors
ON = Last user
OFF = User x
5.1.6
Setting for the user address
Address can be set by rotary switches� Example: User address 23
MB253EN - 11173971, 19A2, Baumer_PMG10-DeviceNet_II_EN
Ground for UB
Voltage supply 10���30 VDC
ELECTRICAL CONNECTION / DEVICENET
Setting for the terminating resistors
Setting for the transmission rate
Setting for the user address
16/27