8.5
Filter setting „10" (range 0.5 ms)
10
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
0
10
8.6
Filter setting „11" (range 1 ms)
10
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
0
10
MB168T1EN - 11184527, 19A2, Baumer_HMC16-T1_II_EN
Filter "10", group delay = 589 μs
1
10
10
Frequency [Hz]
Filter "11", group delay = 1099 μs
1
10
10
Frequency [Hz]
2
3
10
2
3
10
FILTER DIAGRAMS HMCP16
4
10
4
10