10

Technical data

10.1

Technical data - electrical ratings

• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Interference immunity:
• Emitted interference:
• Approvals:
10.2

Technical data - mechanical design

• Size (flange):
• Shaft type:
• Admitted shaft load:
• Protection DIN EN 60529:
• Operating speed:
• Operating torque typ.:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Corrosion protection:
• Explosion protection:
• Connection:
• Weight approx.:
MB075T1 - 11069719
9...30 VDC (HTL)
9...26 VDC (TTL - version R)
5 VDC ±5 % (TTL)
≤100 mA
1024...3072 (as ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
Optical
≤120 kHz
K1, K2, K0 + inverted
HTL
TTL/RS422
(as ordered)
EN 61000-6-2
EN 61000-6-3
CE, UL approval / E217823
ø130 mm
ø16...36 mm (through hollow shaft)
≤300 N axial
≤500 N radial
IP56
≤6000 rpm (mechanical)
15 Ncm
4.9 kgcm
Housing: aluminium alloy
Shaft: stainless steel
-40...+100 °C
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27
Shock 200 g, 6 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions CX (C5-M)
according to ISO 12944-2
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIB T135°C Dc (dust)
(only with option ATEX)
Terminal box
4 kg
Baumer_HOG131_T1_DE_EN_202010_MI_11069719 (20A2)
(ø32)
2
10
Technical data
24