Baumer TA201 Gebruiksaanwijzing - Pagina 26

Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Baumer TA201. Baumer TA201 36 pagina's. Electronic

TA201
Operating mode On the operating mode it is possible:
26
4

Operating mode

Operation and application of the device are described in this chapter.
After switching on the voltage supply, the device is automatically
ready for operation.
-
to read tachometer display F1, e.g. supply speed;
-
to read tachometer display F2, e.g. rpm;
-
read the measurement display F3, e.g. ratio between F1:F2
On the programming mode, it is possible to disable all parameters
(more information see also chapter 5, programming field 2).
Kex functions
Key
Switches to the next operating parameter in the operating mode.
For fast run-through keep the key pressed down.
Key
Switches over between programming and operating mode.
Display
Tachometer display F1
F1 F2 F3
Read the displayed value
Tachometer display F2
F1 F2 F3
Press the key
Read the displayed value
Measurement function F3
F1 F2 F3
Press the key
Read the displayed value
5

Programming mode

This chapter describes the process used to programm the device.
On the programming mode it is possible to adjust the operating pa-
rameters. The programming mode is subdivided into three different
programming fields.
st
1
programming field
In the first programming field it is possible to access and modify all
the operating parameters. Those operating parameters which are dis-
abled on the operating mode are also displayed here. The first pro-
gramming field consists of three lines.
nd
2
programming field
In this programming field the individual operating parameters can be
disabled and enabled for access to the operating level. It is possible
to access disabled operating parameters from the first progr. field.
rd
3
programming field
In the third programming field it is possible to program all machine-
related functions and values as well as the interface parameters.
www.baumerivo.com