TA201
Line 27
Line 28
Line 29
Line 30
Line 31
Line 36
Line 37
30
Scale F3 (multiplier), e.g. to 100.000 for display of an extension
comparison in percentage terms.
* 1,0000
0,0001...9999,99
Update time (display repetition)
0
0.5 s
1 * 1 s
2
2 s
3
3 s
4
5 s
5
10 s
6
20 s
7
30 s
8
60 s
Time out F1 - F3 (see line 21)
On standstill, after expiry of this period:
a reset to zero occurs with
measurement functions 0 to 6
0 * 1 s
1
2 s
2
3 s
3
5 s
4
10 s
5
20 s
6
30 s
7
60 s
8
Time out not operational
9
Time out not operational, with storage of F1, F2 and F3 in the
event of a power failure.
Time unit F1
0 * 1/min
1
1/s
2
1/h
Time unit F2
0 * 1/min
1
1/s
2
1/h
Decimal point for F1
0 * no decimal point
1
0.0
2
0.00
3
0.000
Decimal point for F2
0 * no decimal point
1
0.0
2
0.00
3
0.000
www.baumerivo.com
an update of the display occurs
with function 7 „pulse rate meas. "
0.1 s
0.2 s
0.3 s
0.5 s
1.0 s
2.0 s
3.0 s
6.0 s