Baumer TER8 Gebruiksaanwijzing - Pagina 6

Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Baumer TER8. Baumer TER8 28 pagina's. Temperature measurement, front-flush and low-invasive resistance thermometers

Baumer TER8 Gebruiksaanwijzing
Front-flush and low-invasive resistance
6.

Electrical connection

9 A voltage supply of 8 ... 35 V DC is provided
Switch off supply voltage.
f
„
Connect sensor in accordance with the pin
f
„
assignment.
Output signal
Pt100 (4-wire)
4 ... 20 mA (2-wire),
Iout at pin 2
4 ... 20 mA (2-wire),
Iout at pin 2 and 3
(option "A")
7.

Configuration

Configuring with FlexProgrammer and PC
Connect FlexProgrammer to sensor with cable
f
„
with white connector.
Connect FlexProgrammer to PC and set
f
„
parameters (see FlexProgrammer instructions).
6 / 28
Temperature measurement
TER8
thermometers
Equivalent circuit
+Vs
4 ... 20 mA
Iout
+Vs
4 ... 20 mA
Iout
Operating Instructions
M12-A, 4-pin
4
1
Function
Pt100 11
Pt100 12
Frame ground
+Vs
Iout
n.c.
Frame ground
+Vs
Iout
n.c.
Frame ground
Configurations:
Temperature range
„
„
Measuing unit
„
„
Sensor offset
„
„
Damping
„
„
Alarm value setting
„
„
Online Measuring
Temperature graph
„
„
Data logging
„
„
3
2
Pin
1, 2
3, 4
Plug thread
1
2
3, 4
Plug thread
1
2, 3
4
Plug thread
www.baumer.com