Technical data

10
Technical data
10.1

Technical data - electrical ratings

• Reversal tolerance:
• Linearity tolerance:
• Temperature coefficient:
• Isolation class:
• Calibration tolerance:
• Climatic test:
• Armature-circuit time-constant (τ
• Open-circuit voltage:
• Interference immunity:
• Emitted interference:
GTF 7.08
• Performance:
GTF 7.16
• Performance:
10.2

Technical data - mechanical design

• Size (flange):
• Shaft type:
• Flange:
• Protection DIN EN 60529:
• Torque:
• Admitted shaft load:
• Materials:
• Operating temperature:
• Resistance:
• Connection:
GTF 7.08
• Rotor moment of inertia:
• Weight approx.:
GTF 7.16
• Rotor moment of inertia:
• Weight approx.:
19
≤0.1 %
≤0.15 %
±0.05 %/K (open-circuit)
B
±5%
Humid heat, constant
(IEC 60068-2-3, Ca)
):
<4 µs
A
10...60 mV per rpm (as ordered)
EN 61000-6-2
EN 61000-6-3
0.3 W (speed >5000 rpm)
0.6 W (speed >5000 rpm)
ø115 mm
ø11 mm solid shaft
EURO flange B10
IP55
1.5 Ncm
≤100 N axial
≤200 N radial
Housing: stainless steel / plastic
Shaft: stainless steel
-30...+130 °C
IEC 60068-2-6
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27
Shock 100 g, 6 ms
Screw terminal connector
0.4 kgcm
2
0.9 kg
0.6 kgcm
2
1.1 kg
Baumer_GTF7_II_DE-EN (19A2)