External SCSI Terminator

In order to prevent SCSI signal loss, the provided external SCSI terminator
must be used at the end of the 68-pin SCSI cable. 50-pin SCSI cables may
also use terminators but usually use termination jumpers on the device it-
self. All termination jumpers must be removed when using the external SCSI
terminator.

4-6. Air Circulation System

Fan Replacement

The front and rear fans are both secured by plastic housings. The fan hous-
ings can be removed by pressing in the clip and sliding the housing upward.
AP200 Hardware Reference Guide
Press the clip with a screwdriver to
release.
IMPORTANT: When replac-
ing the fans, be sure that both fans
rotate in the same direction. Use the
manufacturer's sticker on one side
of the fan as a reference. The air
should flow from the rear of the
chassis to the front of the chassis.