Amphenol ePower-Lite Mini Montage Werkinstructies - Pagina 3

Blader online of download pdf Montage Werkinstructies voor {categorie_naam} Amphenol ePower-Lite Mini. Amphenol ePower-Lite Mini 8 pagina's.

Amphenol ePower-Lite Mini Montage Werkinstructies
Step 2:
Strip out ALU-PET foil, evenly disperse and bend the shielding net, ensure the inner ferrule is in close contact
with shielding wire.
ALU-PET foil
Step 3:
Assemble the outer ferrule and crimping to right crimp height (7.5± 0.1 mm), cutting and the jacket.
Item
2 Ports (Include all cable sizes)
L1
Step 4:
Stripping the jacket and cut off the exposed shielding wire of cable, crimping the terminal by right crimping tool.
Recommended manual crimping tool as below (P/N: FX3-0094-000):
5.8± 0.2 mm
Shielding net
L1