7.3
Beam blocker
Uncontrolled reflections of the laser beam can cause malfunctioning of the sensor or disturb people.
Therefore, a beam blocker should be fitted whenever possible to block the beam when there is no target
present. A flat surface (at least approx. 25x25 mm) made of a matte, non-reflecting material is
recommended as the beam blocker. The beam blocker must be mounted parallel to the sensor. The
yellow edge indicator LED must not light when the laser beam strikes the beam blocker.
7.4
Cleaning the front window
Fingerprints, dust and other forms of dirt on the front window can impair the function of the sensor. There
is a high risk of accidentially leaving fingerprints on the windows when mounting the sensor. Make sure
that after the mounting the front windows are cleaned! It is normally sufficient to wipe the glass pane dry
with a clean (!), soft cloth. Alcohol may be used for heavier soiling.
7.5
Checklist for correct mounting
When the SCATEC-2 is mounted correctly:
the green power LED lights as long as the electrical supply is connected
the product overlap faces in the same direction as indicated on the sensor label
the laser beam is focused on the conveying plane into a line about 2 (3)mm long
the laser line focus must be aligned in parallel to the edges to be detected
the yellow edge indicator LED does not light when the laser beam strikes the beam blocker
the yellow edge indicator LED lights as long as an edge is located in the beam
the front windows are clean
Manual SCATEC-2
Version 2021-09
13
www.baumer.com
Baumer Electric AG
Frauenfeld, Switzerland