Dover PSG Mouvex AS80 Installatie, bediening en onderhoud - Pagina 17
Blader online of download pdf Installatie, bediening en onderhoud voor {categorie_naam} Dover PSG Mouvex AS80. Dover PSG Mouvex AS80 19 pagina's.
6.1 Lubrication
The hose is lubricated with a special mixture. MOUVEX
lubricant is recommended to lengthen the service life of
the hose.
It is recommended to change the lubricant when :
• Replacing the hose.
• Replacing the hose due to maintenance operation.
• After 2000 hours of operation.
Amount of lubricant required :
A80 and AS80 pumps require
40 liters of lubricant.
The minimum working or storage temperature for the
pump lubricant is 0°C (32°F).
For use / storage at lower ambient temperatures, it is
necessary to add ethylene glycol to the MOUVEX lubri-
cant. To maintain optimum lubrication, the volume of
ethylene glycol should remain between 4% and 6% of
the total volume of lubricant, and the total quantity of
lubricant present in the pump must be in compliance
with the value specified above.
In any case, the ambient temperature should never be
lower than -20°C (-4°F).
6.2 Hose
Some pumped liquids require the hose to be cleaned
after each operation to prevent solidification of the fluid
inside the hose.
The hose can be easily washed with a cleaning agent
that is compatible with the hose material and the pum-
ped product.
It is recommended that the hose be monitored so that it
can be replaced before any breakdown should occur.
Preventive replacement is advisable.
Temperature threshold values for the liquid pumped
depend directly on the materials that make up the hose.
Refer to technical characteristics on the cover page for
the corresponding values.
It is important to note that the temperature of the pum-
ped liquid influences the limits of use of the pump and
that a rise of the temperature of the pumped liquid has
to come along with a modification of the service pressu-
re / of the speed of rotation so as to respect the limits
defined in § TECHNICAL SPECIFICATIONS and even-
tually of a modification of the shimming of the shoe as
specified in the § SHIMMING THE SHOES.
When required, you can contact our Technical Services
at any time to ask for the information you require.
NT 1101-L00 08.10 A80 - AS80 e
6. MAINTENANCE
6.3 Seals
17/19
6.3.1 SHAFT SEAL 26
The shaft seal 26 must be replaced if lubricant leakage
is observed near the drip strip, located on the rear side
of the pump body 1.
6.3.2 COVER SEAL 10
The cover seal 10 must be checked when removing the
cover 2 and replaced if necessary (see § DISASSEM-
BLING THE COVER).
6.3.3 WINDOW SEAL 46
The window seal 46 must be checked when removing the
window 15 and replaced if necessary (see § SETTING
OF PUMP AT SERVICE PRESSURE NEEDED).