14.1 Short duration (≤ 1 month)
WARNING
Toxic or hazardous fluids
can cause
serious injury.
MOUVEX pumps and motor­driven pumps are well lubricated
when delivered to protect the internal parts during brief sto­
rage in a building where :
• the temperature remains between 10°C and 50°C.
• the relative humidity does not exceed 60%.
• exposure to vibration is limited (maximum movement :
0,05 mm).
• pump is stored in an area sheltered from bad weather and sun.
The pump must be scrapped in compliance with the regulations in
force.
NT 1010­P00 09 20 CC10­24 A e

14. STORAGE

IF PUMPING HAZARDOUS OR TOXIC FLUIDS,
THE SYSTEM MUST BE FLUSHED PRIOR TO
PERFORMING ANY SERVICE OPERATION.

15. SCRAPPING

14.2 Long duration (> 1 month)
We recommend the following procedure for longer periods of
storage :
The recommendations from the manufacturer should be fol­
lowed if the pump is stored with its gear motor.
Pump ports should be filled with a non­corrosive liquid that it
compatible with the pump components in order to prevent
corrosion.
Unpainted external surfaces of the pump (e.g. shafts, cou­
plings, etc.) should be covered in some form of anti­corrosion
protection.
The best storage conditions are inside a building that meets
the conditions set out above.
If inside storage is not possible, the materials should be covered
to prevent direct exposure to sun and bad weather. This protec­
tion should also prevent condensation.
It is recommended to turn the pump by hand every two months
to distribute the lubricant around the interior. Items should
then be placed where there is no risk of damage if they are
moved slightly by vibrations.
During this operation, particular care must be paid to the drainage
stages of the pump (pumped product).
17/18