Follett HCC101OAJS Snelstarthandleiding - Pagina 6

Blader online of download pdf Snelstarthandleiding voor {categorie_naam} Follett HCC101OAJS. Follett HCC101OAJS 8 pagina's. Self-contained chewblet ice machine

Follett HCC101OAJS Snelstarthandleiding
3 – Undercounter/in-cabinet mounting and ventilation (continued)
Using grilles by others/alternate cabinet ventilation
Cabinets with ventilation or louvers other than those provided require special consideration to provide proper ventilation.
Recirculation of hot air will reduce ice machine performance and can cause ice machine outages.
exhaust
All counter ventilation
within 18.00" (45.7 cm) of
air inlet must be blocked to
prevent exhaust-air recirculation
cabinet door
Important specifier notes for using grilles supplied by others/alternate cabinet ventilation
1. Exhaust must be at least 18.00" (45.7 cm) from air intake (exhaust air
must not recirculate with intake air).
2. Cabinet interior must be open to allow for unrestricted exhaust
air flow.
3. Ice transport tube needs minimum 1/4" per foot (2 cm per meter)
pitch toward ice machine and should be secured to prevent dips and
traps from forming.
6
Form# 7030
18.00" (45.7 cm)
minimum
air in
Cabinet door
must mate directly
to air intake gasket
air intake gasket
door & gasket
must mate
directly
Grilles by others/
alternate cabinet ventilation
Grilles by others/
alternate cabinet
ventilation
18.00" (45.7 cm)
minimum
exhaust
Horizon Elite ice machine
4. Ducting must be provided if cabinet door does not mate directly to
air intake gasket.
5. Cabinet interior must provide a minimum clear space of 23.50"
(59.7 cm) high by 25.25" (64.1 cm) deep.
6. Grilles by others must meet minimum requirements for open air
space shown above.
7. Utilities should be conveniently located as shown.
Self-contained 1010, 1410 series ice machine
Minimum open air space
x
= sq. in. of open air space
side
view
y
x
y
n
x
x
n
= (# of openings)
minimum 250 sq. in.
open air space