1. INTRODUCTION
Proper installation and maintenance are essential for maximum satisfaction from your appliance. It is therefore
necessary to carefully read and observe the indications of these instructions for use. The device contents little measure
of coolant R290 (Propane), hydrocarbon which is friendly to the environment, but it is still flammable. During transfer
and installation of the device every caution should be taken, in order to avoid any damage in any part of the refrigeration
circuit.
With reference to avoid the creation of flammable mixture (R290 with air), in case of a leakage in the refrigeration circuit,
the size of the room where the device will be settled should be defined by the amount of the coolant. The room must
have the size of 1m3 for every 8 gr. of the coolant R290 inside the device. The measure of the coolant in the particular
device it is shown on the tag with the serial number (SN) of the freezer in the rear of the appliance.
2. TRANSPORT
(figure 1)
Always transport the appliance in vertical position, do not overturn it and do not load it in leaning position.
3. INSTALLATION OF THE APPLIANCE
Remove the package.
Be sure that your device is stable and in horizontal position.
Perfectly level the appliance by adjusting the adjustable stands that are provided with the appliance.
Never install the refrigerator in a room exposed to direct sun radiation nor in the vicinity of a heat source such as
cooker, a stove, a heater, a fireplace etc.
Avoid installing the appliance in confined rooms, damp, and without airing or in wall recesses.
The clearance behind the appliance must be at least 10 cm distance from the wall or other voluminous objects. This
clearance is the minimum required to ensure normal ventilation of the refrigeration mechanism.
4. ELECTRICAL CONNECTION
Make sure that the feed cable and the socket are appropriate for the appliance power. In case of doubt, contact a
qualified technician. Before inserting the plug in the mains outlet, make sure the voltage mentioned on the nameplate
outside the appliance to the right of the back side, compiles with the one of your network. A discrepancy of +/- 10% is
acceptable. Too high or too low voltage network may seriously damage the compressor. Such damages are not covered
by the guarantee. The appliance must be earthed as prescribed by the relevant legislation whereas it is indispensable
for your personal safety. The manufacturer has provided for earthing in the electrical installation and external surface of
the appliance.
NOTE: Upon start up, running may be noisy. Noise will only last for the engine "running in" time and will dim