DIP Switch
Set device number and speed with DIP switch. DIP switch is shown in the table below.
Function
Device Number
Speed
Table 3-11 for details.
the switch is at ON position, meaning 1.
the switch is at the bottom, meaning 0.
Table 3-11
No.
Description
Set device number with binary system. The left is the lowest order.
For example:
1~5
Binary representation 00110 corresponds to 6 in decimal system.
Set the speed.
All of them are at the bottom
transmission speed is 50kb/s.
Only digit 6 is at ON position
6~8
transmission speed is 80kb/s.
Only digit 7 is at ON position
transmission speed is 100kb/s.
Digits 6 and 7 are at ON position
transmission speed is 125kb/s.
,
,
,
,