Follett H50R5A/W Installatiehandleiding - Pagina 4

Blader online of download pdf Installatiehandleiding voor {categorie_naam} Follett H50R5A/W. Follett H50R5A/W 13 pagina's. Ice and water dispenser
Ook voor Follett H50R5A/W: Bedienings-, onderhouds- en onderdelenhandleiding (17 pagina's)

Ambient specifications

Air Temp
Water Temp
Water Pressure
Plumbing
C25/50 with
remote icemaker remote icemaker integral icemaker integral icemaker
Dispenser drain
Icemaker drain
Dispenser water inlet
Remote IM water inlet
Cond. inlet – w/c only
Cond. drain – w/c only
Note:
Water shut-off recommended within 10 feet (3 m) of dispenser.
Drain to be hard piped and insulated, and maintain at least 1/4" per foot (6 mm per 30.4 cm run) of slope.

Field wiring diagrams

Freestanding dispensers, countertop and wallhung dispensers with integral icemakers
FIELD WIRING DIAGRAM IS
OR TECHNICIAN IN UNDERSTANDING
HOW EQUIPMENT WORKS. ALL FIELD
WIRING MUST BE INSTALLED IN
ACCORDANCE WITH NEC AND LOCAL
ELECTRICAL CODES.
LEGEND
WIRENUT
EQUIPMENT
X
GROUND
B - BLACK
W - WHITE
R - RED
GRN - GREEN
Countertop and wallhung dispensers with remote icemakers
LEGEND
WIRENUT
EQUIPMENT
X
GROUND
B - BLACK
W - WHITE
R - RED
GRN - GREEN
DISPENSER
JUNCTION BOX
GND
GRN
X
B
W
R
100° F/38°C Max.
90°F/32°C Max.
70 P.S.I. Max.
H25/50 with
3/4" FPT
3/4" ID tubing
1/2" MPT
1/2 MPT
3/8" FPT
3/8" FPT
1/4" FPT
1/4" FPT
3/8" FPT
3/8" FPT
1/2" FPT
1/2" FPT
IMPORTANT
INTENDED TO AID ELECTRICIAN
DISPENSER
JUNCTION BOX
GRN
GND
X
B
W
R
Standard electric - 115V, 60 Hz, 1 Ph,
Max. fuse size per circuit - 15 amps
Alternate electric - 230V, 50 Hz, 1 Ph
Max. fuse size per circuit - 15 amps
Electric Power Source
B
W
GND
X
GRN
FUSED
DISCONNECT
50°F/10°C Min. (Best performance below 80˚F/27˚C)
40°F/4°C Min. (Best performance below 70˚F/21˚C)
10 P.S.I. Min.
C25/50 with
3/4" FPT
3/8" FPT
1/2" FPT
1/2" FPT
Electric Power Source
Standard electrical - 115V, 1 Ph, 60 Hz,
Alternate electrical - 230V, 1 Ph, 50 Hz,
B
W
GND
X
GRN
FUSED
DISCONNECT
IMPORTANT
FIELD WIRING DIAGRAM IS INTENDED TO AID ELECTRICIAN
OR TECHNICIAN IN UNDERSTANDING HOW EQUIPMENT WORKS.
ALL FIELD WIRING MUST BE INSTALLED IN ACCORDANCE WITH
NEC AND LOCAL ELECTRICAL CODES.
Electric Power Source
B W
GND
X
GRN
FUSED
LOWER ICEMAKER
DISCONNECT
JUNCTION BOX
(BIN SIGNAL)
W
B
2
ICDI220
H25/50 with
F25/50
3/4" ID tubing
3/4" FPT
3/8" FPT
3/8" FPT
3/8" FPT
1/2" FPT
3/8" FPT
1/2" FPT
1/2" FPT
max. fuse size 20 amps
max. fuse size 15 amps
UPPER ICEMAKER
JUNCTION BOX
(POWER)
GND
GRN
X
W
B