Operational Status
The chart below shows the operational status of various parts when certain switches are turned off or accessories
are removed.
Condition
Pump
Top lid off
OFF
Rear lid off
Drain pan off
On/off switch
in off position
OFF
Beverage
switch in OFF
position
Water bath circuit board operation
The temperature sensor is hard wired directly to the circuit board. The water bath circuit board operates on 24
volts AC. The bath pump will run for 35 minutes whenever ice is dispensed or the bath calls for ice.
Optimal beverage temperature is controlled by the circuit board located in the electrical box. The board monitors
the water bath temperature and holds it to a factory setting. When the Red LED is ON, the bath solenoid, auger
motor, wheel motor and bath pump are energized. Ice will be dispensed into the water bath for 12 seconds, then
stop for 60 seconds. The pump will stay energized, and the circuit board will then monitor the water temperature.
If it is below the set point, the Green LED will come on, the Red LED light will go off, and ice will not dispense
into the water bath. If the temperature of the bath is determined to be above the set point, the Red LED will
remain on. The circuit board has a delay of 60 seconds before more ice is dispensed into the water bath.
LED indicators:
Green – the water bath is at the set temperature.
Red – the bath temperature is above the set temperature and the bath is calling for ice.
Flashing LED indicators:
Flashing Red and Green – the circuit board has gone into an error mode:
Alternate flashing – circuit board has power and is waiting for hopper cover and dispenser top to be
replaced.
Simultaneous flashing – the water bath did not reach set temperature in 40 minutes. Reset this error
mode by turning power off, removing top lid, drain pan or rear lid.
Electrical box
Front View
power on/off
switch
probe
Solenoids
ON
ON
ON
ON
ON
OFF
ON
ON
#1 #2
ice
machine
switches
Auger
Wheel
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
bev. bath
indicator
cold/green LED
warm/red LED
14
Beverage
valves
ON
ON
OFF
OFF
OFF