Dip Switches SW1 & SW2 features.
SW1
1
Working with 1 motor. Use input M1.
2
Feature "close immediately" enable. When the gate is
opening, as soon as the photocells are disengaged, the gate
closes after 5 seconds.
3
First push in an opposite way to release the electro-lock (for
gates with electro-lock only).
4
Extra push while starting disable.
SW2
1
Residential feature enable (while opening the control panel
does not accept any other Start impulse). When gate has
opened, a Start impulse closes the gate without considering
the automatic shutting set on it.
disable. Step by step feature enable also during opening.
2
Enable the indicator of gate movement/position on inputs
10-11 (LOCK).
3
Enable use of resistive safety edge of 8K2.
4
Final push in an opposite way to release the motors both
opening and closing.
6
Fuses description.
F1 - 20A 250V
Output battery protection fuse (27 - 28).
F2 - 20A 250V
Transformer output 24Vac protection fuse.
FR1 - 0,5A 250V Main power supply 230Vac self-repairing protection fuse (non replaceable).
FR2 - 1,6A 250V Self-repairing protection fuse for photocells, electro-lock, flashing light and accessories (non replaceable).
WARNING: High risk of electric shock ! Cut off the main power supply from the panel before touching the fuses (F1 and F2).
We recommend to re-check the wiring before replacing any fuse
7
Remote control storing (recommended to be done with the antenna disconnected).
As START button:
1) Close the gate. Press once the button LEARN; led DL8 starts flashing.
2) Press the remote control button you want to store; led DL8 switched off as confirmation that code has been stored.
You can store up to max. 32 different codes for the Start.
As Pedestrian button:
1) Close the gate. Press twice the button LEARN; led DL8 starts flashing.
2) Press the remote control button you want to store; led DL8 switched off as confirmation that code has been stored.
You can store up to max. 32 different codes for the Pedestrian.
8
Remote control cancellation.
Cancellation of a single code stored into START or PEDESTRIAN:
1) Press at the same time both buttons LEARN and BREAK; led DL8 starts flashing quickly.
2) Within 10 sec. press remote control button you want to cancel; led DL8 switches off to confirm the cancellation.
Cancellation of all codes stored into the control panel:
Press at the same time both buttons LEARN and BREAK for about 10 seconds.
Led DL8 starts flashing quickly and after 10 seconds will switch off confirming the cancellation has been done.
9
Preliminary checks before setting the control panel.
1) Power the control panel and verify that LED Stop, Foto, Foto AP and Costa are on; if this doesn't correspond, re-check the wirings
and or safety devices state. Any NC contact not used, has to be wired/closed.
2) Verify that all safety devices installed in the gate are working properly in order to reduce any possible accident.
3) Verify the correct wirings, keeping in mind that 1
M1 and/or 19-20 for M2.
ON
ON
Residential feature
st
START impulse has to open the gate, otherwise, just swap the wires 17-18 for
Working with 2 motors (M1 + M2).
Feature "close immediately" disable.
Push disable.
Extra push of 2 seconds while starting.
Residential feature disable. Step by step feature enable
also during opening.
Enable electro-lock on inputs 10-11 (LOCK ).
Enable use of mechanical safety edge (N.C. contact)
Final push disable.
OFF