7. SYSTEM SETTING CONFIGURATION
7.1 Jumper Settings (JP3)
Manufacture settings.
Open
JP3
Short
Note A:
JP1, JP2, JP4, JP5, JP6, and JP7 not applicable for the Alpha 580 model.
Note B:
If transmitter low voltage occurs during operation, other than transmitter itself will display visual
warning, it will also send out a low voltage signal to the receiver to activate its external low voltage
warning device. By connecting a horn, buzzer, or siren to the LV-relay output will ensure that the
operator will clearly notice the low voltage warning even in hard to see or hear environments. After
one minute of low voltage warning, to insure maximum safety, both the transmitter power and the
receiver MAIN will be deactivated. For proper battery replacement, you must first turn "off" the
transmitter power, replace the batteries, and then turn the power switch back "on" again to reactivate
the transmitter and the receiver unit.
JP3
System On Work in Progress
Short
JP3
System On Work in Progress
Open
7.2 Security ID Code Setting
The ID code dip-switch is located on the back side of the encoder board (refer to Fig. 5 on page
6) and the decoder/relay board (refer to Fig. 6 on page 7).
Example : ID code
Top location : " 1 "
Bottom location : " 0 "
Low voltage warning only; receiver MAIN will not be deactivated.
After one minute of low voltage warning, the transmitter power and
the receiver MAIN will be deactivated. (see note B)
Transmitter Low
LV Warning
Voltage Occurs
Transmitter Low
LV Warning
Voltage Occurs
10010110
YES
Change Batteries
within 1 Minute
NO
YES
Change Batteries
within 1 Minute
NO
10
Work Resumes
Transmitter and Receiver MAIN Deactivated.
Work Resumes
Only Transmitter Unit Deactivated.