AMQ ACTIV DT Riser Handleiding voor probleemoplossing - Pagina 2
Blader online of download pdf Handleiding voor probleemoplossing voor {categorie_naam} AMQ ACTIV DT Riser. AMQ ACTIV DT Riser 2 pagina's.
Ook voor AMQ ACTIV DT Riser: Installatiehandleiding (5 pagina's), Installatiehandleiding (8 pagina's), Montagehandleiding (9 pagina's)
ISSUES
Issue 1: LED RST flashing
Solution: System reset
Instruction:
1. Ensure the power line, connecting cable and hand set cord are connected correctly.
2. Press the down arrow and hold until the unit reaches its lowest position. Release. Press the up arrow,
holding for at least 7 seconds. The actuators will move the unit down 7mm, then up 7mm.
When the LED displays normally, the reset is complete.
Issue 2: LED displays E01 or E07
Solution: System reset
Instruction:
1. Press any button – LED will display "RST"
2. Reset following Issue 1 instructions.
Issue 3: LED displays H01
Solution: System reset
Instruction:
Reset 18 minutes first, then operate.
Note:
If the above is ineffective, turn off power for 10 seconds before turning back on.
ACTIV DT RISER TROUBLESHOOTING GUIDE | 2
amqsolutions.com