IO Application

Electric Strike

Electric Strike
The Electric Strike is opened when +12 V
is supplied.
The Electric Strike is closed when +12V is
not supplied.
DI2:Trigger Default is High (LowHigh),
When the Open Button is pressed, the door
will be opened.
DI1:Trigger Default is HighLow。
When the electronic circuit connected with the
Electric Strike completely, you should choose
"Negative" in the item Device Relay Output on
the WEB UI in Entrance Setting – GPIO, and
saved.
Please follow Technical Manual to set WEB UI.