Electrolux 726673 Installatie-, bedienings- en onderhoudsinstructies - Pagina 10
Blader online of download pdf Installatie-, bedienings- en onderhoudsinstructies voor {categorie_naam} Electrolux 726673. Electrolux 726673 19 pagina's. Electrolux vertical refrigerator installation, operating and maintenance instructions
A.1 GENERAL INFORMATION
A.1.1 FOREWORD
The purpose of this manual is to provide the necessary
information for the correct installation, operation, use and
maintenance of the appliance.
Consequently, the manual and all the technical documentation
enclosed with the appliance must be kept with the appliance at
all times so that they can be consulted by the technician or end
user. It is important to inform the appliance user about regulations
concerning safety during and after installation.
Read the instructions in the manual carefully before carrying out
any operation whatsoever on the appliance, as they give important
information about the standards and rules governing its
installation and safe use. Improper installation, adjustment,
alteration, service or maintenance can cause property
damage, injury or death. Failure to observe the instructions
in this manual when carrying out any operations on the
appliance will relieve the manufacturer of all liability. Also, the
manufacturer declines any responsibility in the event of
problems caused by the use of non-original spare parts.
No part of this of this manual may be reproduced.
A.1.2 INTENDED USE AND LIMITATIONS
This appliance has been designed for the refrigeration and
preservation of foodstuffs. Any other use is to be considered
improper.
ATTENTION: these appliances are not suitable for installation
outdoors and/or in environments subject to natural elements
(rain, direct sunlight, etc.).
The manufacturer declines all liability for any improper use of
the product.
A.1.3 TESTING
Our appliances have been designed and optimised with
laboratory testing to give high performance and efficiency. The
product has gone through 100% testing and is ready for use.
The certificates guaranteeing that the tests (visual inspection -
electrical test - functional test) have been passed are included
with the appliance and are included in specific enclosures.
(section D.5).
A.1.4 GENERAL SAFETY RULES
The appliance is manufactured in compliance with following
directives:
- Hygiene:
ANSI / NSF 7
- Safety:
UL 471
- CAN / CSA C22.2 No.120 - M91
For model PR43RE1FEU.
A.1.5 CUSTOMER'S RESPONSIBILITIES
A fused disconnect switch or a main circuit breaker (customer
furnished) MUST be installed in the electric supply line for the
appliance. It is recommended that this switch/circuit breaker
have lockout/tagout capability. Before making any electrical
connections to this appliance, check that the power supply is
adequate for the voltage, amperage, and phase requirements
on the rating plate. The customer also must provide a grounded
electrical line cord of suitable capacity for the input specified
on the data plate.
A.1.6 DATA PLATE POSITION
The data plate with all the appliance specifications is located
on the refrigeration unit compartment at the top right hand side.
There is also a plate bearing the appliance's PNC code and
serial number located underneath the logo.
A.1.7 PHYSICAL SAFETY FEATURES, HAZARDS
The appliance has no sharp or projecting parts.
DANGER! DO NOT REMOVE. There are guards on the units to
prevent access to components which require air movement.
A 1.8 IMMEDIATE INSPECT FOR SHIPPING DAMAGE
The container should be examined for damage before and
during unloading. The freight carrier has assumed responsibility
for its safe transit and delivery.
received, either apparent or concealed, a claim must be made
with the delivering carrier. Apparent damage or loss must be
noted on the freight bill at the time of delivery. The freight bill must
then be signed by the carrier representative (Driver). If the bill
is not signed, the carrier may refuse the claim. The supplier can
supply the necessary forms. A request for inspection must be
made to the carrier within 15 days if there is concealed damage
or loss that is not apparent until after the equipment is uncrated.
The carrier should arrange an inspection. Be certain to hold all
contents plus all packing material. Under no circumstances
should a damaged appliance be returned to the manufacturer
without prior notice and written authorization.
A.2 TECHNICAL DATA
A.2.1 MATERIALS AND FLUIDS USED
All areas designed to come into contact with food are in steel
or covered in non-toxic plastic material. An HFC refrigerant, in
compliance with current legal standards, is used in the refrig-
erating units. The type of refrigerant gas used is stated on the
data plate.
A.2.2 DIMENSIONS, PERFORMANCE AND CONSUMPTION
Gross capacity
External dimensions:
- Width
- Depth with door closed
- Depth with door open
- Height
Chamber dimensions:
- Width
- Depth
- Height
Shelf dimensions
- VERSIONS WITH POWER SUPPLY VOLTAGE
120V/1ph/60Hz
Internal temp. range
Max. ambient temp.
Current input (°)
Refrigerant charge R134a
Refrigerant capacity (R134a) (¹)
Refrigerant capacity (R134a) (²)
No. and type of defrostings (*)
(°) At room temperature 104°F/40°C.
(¹) At room temperature +95°F/+35°C, condensation
temperature 131°F/+55°C and evaporation temperature
14°F/-10°C.
(²) ASHRAE PERFORMANCE ambient temperature 89.6°F/
+32°C, condensation temperature 129.92°F/+54.4°C and
evaporation temperature 44.96°F/+7.2°C.
(*) Auto (by electronic board)
10
If damaged equipment is
105.67gal.
23.62"
26.18"
47.24"
83.15"
21.26"
21.65"
58.42"
20.87"x15.75"
530x400mm
35.6°F/50°F
+2°C/+10°C
+109.4°F
0.617lbs
max each 18h x max 30'
400 Iiters
600mm
665mm
1200mm
2112mm
540mm
550mm
1484mm
+43°C
5 A
280 gr
260 W
556 W