Bosch Ascenta SHE4AM12U Reparatie-instructie - Pagina 21

Blader online of download pdf Reparatie-instructie voor {categorie_naam} Bosch Ascenta SHE4AM12U. Bosch Ascenta SHE4AM12U 27 pagina's.
Ook voor Bosch Ascenta SHE4AM12U: Instructies voor reparatie (50 pagina's)

Bosch Ascenta SHE4AM12U Reparatie-instructie
Power
module
6.1.4.3 Door latch
SHE5AM digital display
E:06 Sensor error
Door latch sensor not detected,
functional safety error.
Align door latch above sensor
(located inside inner door).
Sensor located
under tray
Sensor (at top
of inner door)
702_58300000130262_ara_en_b
SHE4AM / SHX3AM
LED display
Door latch (on tank)
6.1.4.4 Heating (heat pump)
SHE5AM digital display
E:08 No load in heat pump
No water in heat pump
Check water supply
E:09 Burn through / safety relay error
Power module controlling relay not
switching / stuck closed
Replace power module
E:10 Resistance too high
Heater resistance too high
Replace heat pump
E:11 NTC1 / NTC 2 failure (absolute /
symmetry)
NTC1 to NTC 2 internal check
failed, functional safety error.
Replace heat pump
E:12 Heater NTC's comparison check
failed
Heater
NTC's
resistances
Replace heat pump
E:13 Water temperature too high
Boil protect level (75ºC / 167ºF)
exceeded, functional safety error.
Replace heat pump
SHE4AM / SHX3AM
LED display
Same LED display
shows
for
codes E:08 – E:13.
have
different
Page 21 of 27
error